1.SCOPE 范圍 | This specification shall be applied to electret condenser microphone(ECM) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
2.MODEL NO. 產品型號 | H4015P006A | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
3 ELECTRICAL CHARACTERISTICS 電氣特性 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Temp. 環境溫度 | 20 ± 2℃ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Room Humidity 相對濕度 | 65 ± 5﹪ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
4.MEASUREMENT CIRCUIT 測試電路 |
5. TYPICAL FREQUENCY RESPONSE CURVE (FAR FIELD) 頻響曲線 |
6.DIMENSIONAL DRAWING 外形圖: |
7.RELIABILITY TEST 可靠性測試 | ||
7.1 VIBRATION TEST 振動測試 | 1 minute frequency from 10Hz to 55Hz, amplitude 1.52mm, the vibration in three directions test 2 hours, the sensitivity deviation range of ± 3dB 1分鐘頻率變化從10Hz到55Hz,振幅在1.52mm,在三個方向測試振動2小時,靈敏度偏離范圍在±3dB | |
7.2 DROP TEST 跌落測試 | Three directions with the regular packaging of free fall from 1 meter at the concrete floor, the sensitivity range of ± 3dB deviation from the 以正規包裝的三個方向從1米高處自由落到混凝土地面時,靈敏度偏離范圍在±3dB | |
7.3 TEMPERATURE TEST 溫度測試 | -After exposure at 70℃ for 72 hours ,sensitivity to be within ±3dB from initial sensitivity 在70℃環境中維持72小時,靈敏度偏離范圍在±3dB. (The measurement to be done after 3 hours of conditioning at room temperature 測試在室內溫度下放3小時后進行) -After exposure at -20 ℃ for 72hours,sensitivity to be within ±3dB from initial sensitivity 在-20 ℃環境中維持72小時,靈敏度偏離范圍在±3dB. (The measurement to be done after 3 hours of conditioning at room temperature測試在室內溫度下放3小時后進行) | |
7.4 HUMIDITY TEST 濕度測試 | After exposure at 40℃ and 90﹪ relative humidity for 72 hours ,sensitivity to be within ±3dB from initial sensitivity 在40℃溫度和90﹪相對濕度的環境下持續72小時,靈敏度偏離范圍在±3dB. (The measurement to be done after 3 hours of conditioning at room temperature測試在室內溫度下放3小時后進行) | |
7.5 Impact test 沖擊試驗 | The width of 11ms, acceleration 150M / S 2 half sine pulse, 10 times in the three directions tested, sensitivity to be within ±3dB from initial sensitivity 在寬度為11ms,加速度為150M/S2的脈沖半正弦波,在三個方向測試10次,靈敏度偏離范圍在±3dB | |
7.6 TESTCONDITION 測試條件 | StandardTestCondition: a)Temperature:+15℃~+35℃ b)Humidity:45%-75% c)Pressure:86 kPa -106kPa 標準測試條件: a)環境溫度:+15℃~+35℃ b)相對濕度:45%-75% c)大氣壓力:86 kPa -106kPa Judgement Test Condition: a) Temperature:(20±2)℃ b) Humidity:60%-70% c) Pressure:86 kPa -106kPa 判定測試條件 : a) 環境溫度: (20±2)℃ b)相對濕度: 60%-70% c)大氣壓力: 86 kPa -106kPa | |
8 TEMPERATURE CONDITIONS 溫度條件 | ||
8.1 STORAGE TEMPERATURE 貯存溫度: | -20℃ ~ +70℃ | |
8.2 OPERATING TEMPERATURE 操作溫度: | -20℃ ~ +70℃ |
9.REGARDING THE SOLDERING OPERATION 焊接注意事項 Every ECM contains a FET with microphone boby.This FET is easy to damageable from excessive heat and electrical shock.Proper attention for the soldering work is required same as followings. 每個ECM都包含有個FET.FET在過熱和電流沖擊下容易損壞。應遵循以下焊接操作規程: |
1 -Recommend to use 15W ~ 35W ceramic soldering iron and apply 330±20℃temperature range 推薦使用功率在15W-17W,溫度變化范圍在330±20℃的陶瓷電烙鐵。 |
2 -Soldering should be accomplished within 2 seconds at each terminal so as not to be overheated. 為防止過熱,焊接應在2秒內完成。 |
3 -ECM shall be soldered fixed on the metal block(heat sink)which has the higher radiation effects. Heat sink shall contact with each of ECM. 應把駐極體傳聲器固定在散熱良好的金屬裝置(散熱板)上進行焊接. |
4 -The pin hole soldering shall be avoided. 焊接后,各焊點不應出現砂眼(焊錫小孔)現象. |
5 -E.C.M may easily destroyed by the static electricity,and the countermeasure for eliminating the static electricity(the ground for soldering copper,for worktable and for human body)shall be executed. 駐極體傳聲器容易受靜電破壞,應采取防靜電措施(焊接器具,工作臺,操作人員人體應接地) |
|