No. | Item | Standard |
1 | Sensitivity | -56±2dB(0dB=1V/Pa) |
2 | Output Impedance | ≤2.2KΩ |
3 | Directivity | Omnidirectional |
4 | Frequency Range | 20-16,000Hz |
5 | Operation Voltage | DC 1.0V-10V |
6 | Standard Power Supply | DC3.0V |
7 | Min Operation Voltage | 1.0V |
8 | Current Consumption | ≤0.5mA |
9 | Signal to Noise Ratio | ≥60dB |
Item | Test Condition | Minimum | Standard | Maximum | Unit |
Sensitivity | f=1kHz,P=1Pa | -60 | -58 | -56 | dB |
Output impedance | f=1kHz, P=1Pa |
|
| 2.2k | Ω |
Current Consumption |
|
|
| 0.5 | mA |
Signal to Noise Ratio | f=1kHz, P=1Pa | 40 |
|
| dB |
Decreasing Voltage | f=1kHz, P=1Pa |
|
| -3 | dB |
Sound Pressure Level | f=1kHz | 110 |
|
| dB |
Weight | Less than:0.35g | |
Soldering Heat Shock | To be no interfere in operation after soldering heat shock, Temperature 260℃±5℃ for 3±0.5 seconds. | |
Terminal Mechanical Strength | To be no interfering in operation after pulled the terminal with 1kg strength for 1 minute. | |
Absolute maximum Ratings | Operating Voltage | 10V |
Storage temperature range | -25~+70℃ | |
Operating temperature range | -20~+60℃ |
Vibration Test | To be no interference in operation after vibration 10Hz to 50Hz for 1 minute full amplitude 1.52mm for 2 hour at three axises. |
Drop Test | To be no interference in operation after dropped to concrete floor each one Time from 1 meter height at three directions in state of packing. |
Temperature Test | After exposure at 70℃ for 200 hours, sensitivity to be within ±3dB from initial sensitivity. (The measurement to be done after 2 hours of conditioning at 20℃) After exposure at -25℃ for 200 hours, sensitivity to be within ±3dB from initial sensitivity. The measurement to be done after 2 hours of conditioning at 20℃) |
Humidity Test | After exposure at 60℃±2℃ and 90 to 95 % relative humidity for 200 hours, sensitivity to be within ±3dB from initial sensitivity. |
Temperature Cycle Test | After exposure at -25℃ for 30 minutes, at 20℃ for 10 minutes, at 70℃ for 30 minutes, at 20℃ for 10 minutes, 5 cycles, sensitivity to be within ±3dB from initial sensitivity. |